This Maine Municipal Association publication is presented for "Classroom Use Only."  Its intended use is to stimulate and aid in discussion and role playing within a classroom setting.

ELECTRIC RATE SCHEDULE                                                                             Page 150.00
CENTRAL MAINE POWER COMPANY                                                             Thirty-First Revision

RATE SL
STREET LIGHTING SERVICE
[This is the pricing schedule for the type of lights being used for all towns & schools.]

AVAILABILITY

This rate is available for street lighting service furnished on a dusk-to-dawn basis. The Company will furnish, install and/or maintain street lights on the distribution system of the Company for purposes of providing street lighting service pursuant to this rate schedule and as is authorized in writing by a governmental entity (referred to as the "customer").

TERM OF SERVICE

The term of service under this rate schedule shall be on a continuing basis. Requests for additions, changes or removals for street lighting service may require 90 days' advance written notice.

BASIC RATE PER MONTH

I . Full Service Lighting (Fixtures, Energy and Maintenance)

Full Service Lighting is defined as service: 1) with aerial feed requiring not more than one section extension of wire and with Company-standard luminaries, lamps, and brackets not over 6 feet in length, on distribution system poles in use by the Company for other purposes, on other poles provided and owned by the Company at the request of the customer, or on poles acceptable to the Company and supplied by the customer; or 2) with not over 125 feet of underground feed per luminaries per circuit through customer's duct lines and with Company-standard luminaries and lamps on customer's poles and brackets. Under Full Service Lighting the Company owns the luminaries, lamps and brackets.

(a) Standard Lighting

The following Standard Lighting fixtures are available as a Full Service Lighting option:

Type
Lamp

Type
Luminaire

Rated
Lamp
Watts
Rated
Input
Watts
Rated
Lumens
Monthly Rate
Per Luminaire
High Pressure Cutoff 50 65 4000

$11.62

Sodium *Open 70 95 6300

11.54

  Cutoff 70 95 6300

11.68

  Post Top 100 130 9500

13.60

  Cutoff 100 130 9500

13.60

  Post Top 150 195 16000

17.11

  Cutoff 150 195 16000

15.32

  Flood 150 195 16000

19.21

  Cutoff 250 300 29000

21.63

  Flood 250 300 29000

22.09

  Decashield 250 300 29000

24.59

  Cutoff 400 465 50000

27.96

  Flood 400 465 50000

28.24

  Decashield 400 465 50000

32.71

  Flood 1000 1100 140000

67.85

*The open bottom sodium fixture is not available for roadway lighting without the express consent of the Company.

Effective Date: For service rendered on and after March 24, 1998

Michael R. Cutter,
Vice President

Docket No. 97-646